Air conditioner maintenance checklist (2 figures)
The HVAC Maintenance Interval Table carries 2 published figures read from 2 sources' own pages, from 2 to 5 year, read 29 October 2026.
CoilDesk sells its own paid plan in this category (our pricing). It is not counted here: every figure in this index is another provider's own published price, read from its own page.
4 of the 9 named sources read in full publish a figure; 5 publish none, read 29 October 2026.
By task and system size / charge threshold
| Breakdown | Median | Range | Sources |
|---|---|---|---|
| task statutory air-conditioning inspection | 5 year (one figure) | one figure, no range | 1 |
| task refrigerant leak check | 2 year (one figure) | one figure, no range | 1 |
| task refrigerant leak check | 20 % (one figure) | one figure, no range | 1 |
| task refrigerant leak check | 15 month (one figure) | one figure, no range | 1 |
| system size / charge threshold 500 lb+ commercial or industrial process refrigeration | 3 month (one figure) | one figure, no range | 1 |
Every figure, with its source
One row per published figure: the figure as the source's own page publishes it, the page, and the day it was read. A figure that is not on a page we read is not on this one.
| Source | Figure | Breakdown | Read |
|---|---|---|---|
| eCFR - 40 CFR 82.157 appliance maintenance and leak repair | 30 % | refrigerant leak check | 2026-10-26 |
| eCFR - 40 CFR 82.157 appliance maintenance and leak repair | 20 % | refrigerant leak check | 2026-10-26 |
| Justice Laws - Federal Halocarbon Regulations, 2022 (SOR/2022-110) | 15 month | refrigerant leak check | 2026-10-29 |
| eCFR - 40 CFR 82.157 appliance maintenance and leak repair | 10 % | refrigerant leak check | 2026-10-26 |
| GOV.UK - a guide to air conditioning inspections in buildings | 5 year | statutory air-conditioning inspection | 2026-10-29 |
| eCFR - 40 CFR 82.157 appliance maintenance and leak repair | 3 month | 500 lb+ commercial or industrial process refrigeration | 2026-10-26 |
| GOV.UK - checking F gas equipment for leaks | 2 year | refrigerant leak check | 2026-10-26 |
The sentence each figure was read from (7)
- eCFR - 40 CFR 82.157 appliance maintenance and leak repair, read 2026-10-26:
(ii) 30 percent leak rate for industrial process refrigeration equipment; and
- eCFR - 40 CFR 82.157 appliance maintenance and leak repair, read 2026-10-26:
(i) 20 percent leak rate for commercial refrigeration equipment;
- Justice Laws - Federal Halocarbon Regulations, 2022 (SOR/2022-110), read 2026-10-29:
contain more than 10 kg of halocarbon, must conduct a leak test of its components that contain a halocarbon at least once every calendar year and no more than 15 months since the previous test.
- eCFR - 40 CFR 82.157 appliance maintenance and leak repair, read 2026-10-26:
(iii) 10 percent leak rate for comfort cooling appliances or other appliances with a full charge of 50 or more pounds of refrigerant not covered by (c)(2)(i) or (ii) of this section.
- GOV.UK - a guide to air conditioning inspections in buildings, read 2026-10-29:
A revised air conditioning inspection report would be required every 5 years from the date of the initial inspection.
- eCFR - 40 CFR 82.157 appliance maintenance and leak repair, read 2026-10-26:
ommercial refrigeration and industrial process refrigeration appliances with a full charge of 500 or more pounds, leak inspections must be conducted once every three months until the owner or operator can demonstrate through the leak rate calculations required under paragraph (b) of this section that the appliance has not leaked i
- GOV.UK - checking F gas equipment for leaks, read 2026-10-26:
For example, with a leak detection system you must check a product that contains F gas equivalent to 5 tonnes of carbon dioxide every 2 years.
Read in full, publishes no figure
5 named sources were read in full on the dates shown and print no usable figure. They are counted, never filled in.
- ENERGY STAR - heating and cooling maintenance checklist, read 2026-09-29: read in full and no accepted figure on the page
- US EPA - stationary refrigeration leak repair requirements, read 2026-09-26: every candidate on the page was refused
- legislation.gov.uk - Energy Performance of Buildings (England and Wales) Regulations 2012, reg. 18, read 2026-09-29: read in full and no accepted figure on the page
- energy.gov.au - household heating and cooling, read 2026-10-29: every candidate on the page was refused
- Your Home (Australian Government) - heating and cooling, read 2026-09-29: every candidate on the page was refused
Methodology
Every row is a verbatim sentence read from the named source's own page through our fetch service on the date shown, hash-pinned to the stored read (the sha of the page's visible text; the raw page is mirrored to R2).
4 of the 9 named sources that could be read published a usable figure; 5 published none and are recorded as not published, never filled in; 1 could not be read (blocked, dead or unreachable) and count nowhere.
The headline figures (median, minimum, maximum, quartiles) are over ONE figure per source in year (a source's median where its page yielded several accepted sentences), so N counts sources, never sentences; 97 candidate sentence(s) were refused by a reviewer with the reason recorded.
The fuller derivation this dataset is chartered to grow into (not yet what the figures above are; they are each source's own published figure as read): one row per task x jurisdiction x system-size threshold: the interval each authority sets and whether it is LAW or GUIDANCE - ENERGY STAR's annual pre-season check-up (cooling in spring, heating in fall) and monthly filter inspection; the US EPA section 608 leak-rate triggers (10% comfort cooling, 20% commercial refrigeration, 30% industrial process) and the once-per-calendar-year leak inspection they start for a 50 lb+ appliance; the GB F-gas leak-check frequency by tonnes of CO2-equivalent (12, 6 and 3 months, doubled with automatic leak detection); the GB air-conditioning inspection at no more than five years for systems over 12 kW; the GB landlord gas safety check at no more than 12 months; Canada's annual leak test (no more than 15 months apart) for a large system over 10 kg of halocarbon; and Australia's service-before-peak-use guidance.
The derivation nobody publishes is the single calendar a contractor can run from it: for each system size and market, the binding (strictest lawful) interval per task, the minimum visits per year it implies, and the gap between that legal floor and the two visits a year the maintenance-plan index shows plans selling
97 candidate sentences on these pages were refused by a reviewer; each refusal and its reason is recorded in the review ledger.
Sources (10)
- ENERGY STAR - heating and cooling maintenance checklist(the publisher's own terms; quoted for reporting and comment)
- eCFR - 40 CFR 82.157 appliance maintenance and leak repair(the publisher's own terms; quoted for reporting and comment)
- US EPA - stationary refrigeration leak repair requirements(the publisher's own terms; quoted for reporting and comment)
- GOV.UK - checking F gas equipment for leaks(the publisher's own terms; quoted for reporting and comment)
- GOV.UK - a guide to air conditioning inspections in buildings(the publisher's own terms; quoted for reporting and comment)
- legislation.gov.uk - Energy Performance of Buildings (England and Wales) Regulations 2012, reg. 18(the publisher's own terms; quoted for reporting and comment)
- legislation.gov.uk - Gas Safety (Installation and Use) Regulations 1998, reg. 36(the publisher's own terms; quoted for reporting and comment)
- Justice Laws - Federal Halocarbon Regulations, 2022 (SOR/2022-110)(the publisher's own terms; quoted for reporting and comment)
- energy.gov.au - household heating and cooling(the publisher's own terms; quoted for reporting and comment)
- Your Home (Australian Government) - heating and cooling(the publisher's own terms; quoted for reporting and comment)
Cite or embed this figure
Cite or embed this figure
The HVAC Maintenance Interval Table carries 2 published figures read from 2 sources' own pages, from 2 to 5 year, read 29 October 2026.
4 of the 9 named sources read in full publish a figure; 5 publish none, read 29 October 2026.
HVAC Maintenance Interval Table, task statutory air-conditioning inspection: median 5 year across 1 source, read 29 October 2026.
HVAC Maintenance Interval Table, task refrigerant leak check: median 2 year across 1 source, read 29 October 2026.
HVAC Maintenance Interval Table, task refrigerant leak check: median 20 percent across 1 source, read 29 October 2026.
HVAC Maintenance Interval Table, task refrigerant leak check: median 15 month across 1 source, read 29 October 2026.
HVAC Maintenance Interval Table, system size / charge threshold 500 lb+ commercial or industrial process refrigeration: median 3 month across 1 source, read 29 October 2026.
Cite as: "CoilDesk HVAC Maintenance Interval Table", updated 2026-11-13, https://coildesk.com/datasets/hvac-maintenance-interval-table/.
Download the CSV (7 rows, computed 2026-11-13)
Questions this data answers
How often must - and how often should - each HVAC maintenance task be done: the pre-season check-up, the filter change, the refrigerant leak check, the landlord gas safety check and the statutory air-conditioning inspection, by jurisdiction and by system size?
The HVAC Maintenance Interval Table carries 2 published figures read from 2 sources' own pages, from 2 to 5 year, read 29 October 2026.
Where do the figures in the HVAC Maintenance Interval Table come from?
Every figure is quoted from its source's own page and dated (last read 29 Oct 2026). 9 named sources were read and 4 publish a figure; the 5 that publish none are recorded as not published, never estimated.